Rackmount PC and Server RPCS-2

Rackmount PC and Server RPCS-2

The RPCS systems are a family of rugged rackmount computers/servers. designed to support severe environmental conditions. These solutions include:

Last generation of DP motherboards in Enhanced-Extended ATX (EE-ATX), E-ATX and ATX frame;
Fixed or Hot-swappable Hard Disk drives;
Fixed or Hot-swappable full redundant AC/DC power supply;
COTS modules, such as motherboard, power supply, mass storage device integrated into a rugged mechanical frame;
IPMI controller;
Suitable for Virtual Systems like Hyper-V, VMWare ESXi, ProxMox.

The RPCS systems are a family of rugged rackmount computers/servers. designed to support severe environmental conditions. These solutions include:

Last generation of DP motherboards in Enhanced-Extended ATX (EE-ATX), E-ATX and ATX frame;
Fixed or Hot-swappable Hard Disk drives;
Fixed or Hot-swappable full redundant AC/DC power supply;
COTS modules, such as motherboard, power supply, mass storage device integrated into a rugged mechanical frame;
IPMI controller;
Suitable for Virtual Systems like Hyper-V, VMWare ESXi, ProxMox.

Additional information

CPUs

One or two Intel® Xeon® E5-2600 series processors

Hard Disks

Up to 3TB of Hot-swappable SAS/SATA 2.5’’ Storage

Motherboard

X9 SuperMicro Series Motherboard

RAM

Up to 1TB in 16 modules

Dimensions

88mm x 446mm x 635mm

Rack mount

19’’ 2U standard rack installation: by means of Jonathan lateral slides and frontal handhelds

Weight

Approximately 14Kg (30 lbs)

Frontal interface

6 slots for Hot Swappable SAS/SATA 2.5’’ disk, CD/DVD/RW, 4 USB 3 slots for Hot Swappable SAS/SATA 2.5’’ disk, CD/DVD/RW, 2 USB

Fan

4 Fan modules with PWM Control

Power Supply

Dual Redundant AC inlet, Hot Swappable, Power Supply up to 2 x 650W

Front panel, controls and indications

Frontal cover removable by key lock, Main Power, Power Supply, System, Overheat FAN, LAN, HDD

Color

Gray RAL-7030, Black

POWER SUPPLY SPECIFICATIONS

Tolerances Voltage: 90 ÷ 264 Vac
Frequency 47 ÷ 63 Hz
Power 650 VA Max
as per MIL STD 1399-300B sect. 5.3.1
Line current Surge (inrush): 30 Apk @115V; ≤ 15 Apk @ 230V
Operating ≤ 10 A rms @ 115V; ≤ 5 A rms @ 230V
as per MIL STD 1399-300B sect. 5.3.6
Current waveform Percent coeff.: 5000/fH @ 50Hz nominal freq.
Percent coeff. 6000/fH @ 60Hz nominal freq.
as per MIL STD 1399-300B sect. 5.3.7
Emergency condition (Power supply and Hot swap) Interruptions: 70 ms (bus transfer),
2 min(re-configuration) as per MIL STD 1399-300B sect. 5.3.4
Voltage and frequency transient 230 Vrms ±20% & 50Hz ±5,5% @ 230 V, 50 Hz115 Vrms ±20% & 60Hz ±5,5% @ 115 V60 Hz as per MIL STD 1399-300B sect. 5.3.2
Leakage current ≤ 2 mA rms, as per MIL STD 1399-300B sect. 5.3.9
Insulation resistance ≥ 10 MOhm @1000 Vac, as per MIL STD 1399-300B sect. 5.3.10
Electrical continuity ≤ 25 mOhm
ENVIRONMENTAL SPECIFICATIONS

Operating Temperature -5° to +50°C (with TCS Active), as per MIL-810F methods 501.4 and 502.4
Storage and Non-Op Temperature -40°C to +70°C, as per MIL-810F methods 501.4 and 502.4
Operating Altitude Up to 10,0000 ft. a.s.l., as per MIL-810F method 504
Non-op Altitude Up to 40,000 ft. a.s.l., as per MIL-810F method 504
Humidity Up to 95% Non-Condensing, 30° to 60°C 48 hours, as per MIL-810F method 507.4
Vibration 0,5g RMS 5 to 50Hz, as per MIL STD 167-1A, Type I
Shock ±40g, 11 ms half sine, as per MIL STD 810F, method 516.5, proc. I
Roll ± 22,5 ° period 10 s, as per AECTP-400-3, method 418
Pitch ± 7,5 ° period 5 s, as per AECTP-400-3, method 418
Safety Regulations EN 60950, RoHS, REACH, CE
Reliability 10 Years Operating Life
Maintainability <20 minutes @ Line-Replaceable Unit (LRU) Level
EMC SPECIFICATIONS

CE102 Conducted Emissions through Power Leads, 10KHz ÷ 10MHz, as per MIL STD 461F – Sect. 5.5
CS101 Conducted Susceptibility through Power Leads, 30Hz ÷ 150Hz, as per MIL STD 461F – Sect. 5.7
CS114 Conducted Susceptibility, bulk cable injection, 10 kHz ÷ 200 MHz, as per
MIL STD 461F – Sect. 5.13
CS115 Conducted Susceptibility, bulk cable injection, impulse excitation, 30 Hz pulses for 1 min., as per MIL STD 461F – Sect. 5.14, fig. CS-115-1
CS116 Conducted Susceptibility, damped sinusoidal transients, cables and power
leads, 10 kHz ÷100 MHz, freq: 0,01; 0.1; 1; 10; 30; 100 MHz as per MIL STD 461F – Sect. 5.15, fig. CS-116-1 and -2
RE101 Radiated Emissions, magnetic field, 30 Hz ÷ 100 kHz as per MIL STD 461F – Sect. 5.16
RE102 : Radiated Emissions, electric field, 10 kHz ÷ 18 GHz as per MIL STD 461F – Sect. 5.17
RS101 Radiated Susceptibility, magnetic field, 30 Hz ÷ 100 kHz as per MIL STD 461F – Sect. 5.19, fig. RS 101-1
RS103 Radiated Susceptibility, electric field, 2MHz ÷ 18GHz., as per MIL STD 461F – Sect. 5.20
Title Type Size
560-00621-000 application/pdf 426 KB

PRODUCT CODE 560-00621-000 - Need Help? Contact Us Leave Feedback