UHF Avionic Amplifier

UHF Avionic Amplifier

The UHF ICU equipment is an “UHF Integrated Cositing Unit” designed with the aim to improve the technical characteristics of UHF systems.
This unit provides signal amplification over the 225 ÷ 400MHz range.
Its Output Power is 50W with an input signal of 2 W.
This amplifier is equipped with a tunable fast filter module in the 225 ÷ 400MHz range that uses PiN-Diode array technology;
this allows high RF performance with a 10bit interface that provides high tuning precision.
The Filter module supports medium power RF signals, and provides fast switching speed and reduced dimensions, thus beating the technical limitations typical of other technologies (Manual Tunable Filters or Filter Banks).

The UHF ICU equipment is an “UHF Integrated Cositing Unit” designed with the aim to improve the technical characteristics of UHF systems.
This unit provides signal amplification over the 225 ÷ 400MHz range.
Its Output Power is 50W with an input signal of 2 W.
This amplifier is equipped with a tunable fast filter module in the 225 ÷ 400MHz range that uses PiN-Diode array technology;
this allows high RF performance with a 10bit interface that provides high tuning precision.
The Filter module supports medium power RF signals, and provides fast switching speed and reduced dimensions, thus beating the technical limitations typical of other technologies (Manual Tunable Filters or Filter Banks).

Additional information

Operative Mode

Half Duplex Operating Mode

Operating frequency

225 ÷ 400 MHz

Bypass

Automatic 225 ÷ 400 MHz, Manual 30 ÷ 400 MHz

Tuning Time

< 40 μs

Receiver Gain

10.0 dB

Receiver Noise Figure

< 9.0 dB

Max IP3 RX signal

52 dBm @ 5 & 10% offset

Minimum selectivity

-35 dB @ > ± 3.0%, -55 dB @ > ± 5.0%

Spurious in reception

3%

Broadband Noise

-140 dBm/Hz @ > 5%

RF Input Power for Transmission

2 W (-0/+1 W)

RF Output Power in Transmission

Minimum level of harmonic -70 dBc (2°), Noise in transmission < -80 dBc, UHF 25 W (AM) ± 1 dB, UHF 50 W (FM) ± 1 dB

ENVIRONMENTAL SPECIFICATIONS

Temperature Operating min -20°C max + 55°C
Storage min -40°C max +75°C
Operating at 30’ min -40°C max +70°C
Altitude Operating and not operating up to 15.000[ft]
Humidity 95% @ 50°C Non condensed (Sect. 6, Cat. A – RTCA/DO-160F)
Vibration Vibration : 0.7 grms 5 to 50Hz (Sect. 8, Cat. B – RTCA/DO-160F)
Shock 20 g 11ms (Sect. 7, Cat. B – RTCA/DO-160F)
Acceleration MIL-STD-810G method 513.6 procedures I and II